PSI VUV About Database

PES 10.7-11.5 eV

Citation 10.1063/5.0142194
Type Photoelectron spectrum
T / K 298
Source Effusive
Resolution / meV 6
Flux normalization No
Comments Effusive pure sample, measured at PLEIADES Beamline at Synchrotron Soleil
Photon energy: 30 eV
Sample container held at -40°C
Energy Axis in binding energy (Photon energy - kinetic energy)
Measured with hemispherical analyzer
Date & facility 2021 PLEIADES
Date entered 2023-08-23
MG

Simulation X+ 2Π

Citation 10.1063/5.0142194
Type Franck-Condon simulation
Further references 10.1063/5.0142194
Comments Wavepacket dynamics simulation, for details refer to 10.1063/5.0142194
Date entered 2023-08-23
MG

PES 14.6-17.4 eV

Citation 10.1063/5.0142194
Type Photoelectron spectrum
T / K 298
Source Effusive
Resolution / meV 6
Flux normalization No
Comments Sharp peaks caused by N2 contamination
Date & facility 2021 PLEIADES
Date entered 2023-08-23
MG

PES 17.7-18.3 eV

Citation 10.1063/5.0142194
Type Photoelectron spectrum
T / K 298
Source Effusive
Resolution / meV 6
Flux normalization No
Date & facility 2021 PLEIADES
Date entered 2023-08-23
MG

PES 18.9-20.4 eV

Citation 10.1063/5.0142194
Type Photoelectron spectrum
T / K 298
Source Effusive
Resolution / meV 6
Flux normalization No
Comments Peak below 18.8 eV caused by N2
Date & facility 2021 PLEIADES
Date entered 2023-08-23
MG