Citation | 10.1063/5.0010035 |
---|---|
Type | Mass-selected threshold photoelectron spectrum |
Further references | DOI beamline: 10.1107/S0909049512010588 DOI instrument: 10.1063/1.4937624 DOI experiment: 10.1063/1.4918634 |
T / K | 215 |
Source | microwave discharge flow tube reactor |
Resolution / meV | 17 |
Flux normalization | yes |
Comments | Species created in a flow discharge reactor by a mix between acetonitrile and atomic fluor 1 ms of mixing time, Temperature in the reactor: room temperature, pressure in reactor: 1 Torr, total flow in reactor: 1200 sccm, DC extraction field used: 35 V/cm, mass resolving power: 1900, energy scale with a precision of 5 meV, calibrated with methyl radical. Translational temperature of the radicals: 215 K. The adiabatic energy takes into account the Renner-Teller effect as referred in 10.1063/1.5011152 |
Date & facility | 2020 SOLEIL Synchrotron, DESIRS Beamline |
Date entered | 2024-07-23 |